Skip to content

Manning Hospital

Improving health care services for the wider NSW region

Bonacci Group provided structural and civil engineering services for the $25 million Manning Hospital Redevelopment located in Taree for our client, Health Infrastructure.

The project features a new 2-level sub-acute facility with undercroft parking on the Manning Base Hospital Campus adjacent to High Street on a building area of approximately 75m x 18m. 

Other features include:

  • Braced frame with columns at 8.4m x 8.4m grid in accordance with HI guidelines
  • Lateral resistance provided by shear walls and lift shaft
  • Post-tensioned flat slab adopted for suspended levels
  • Design allowance for suture additional level over

Location: Taree, NSW

Sector: Health 

Services: Structural and Civil Engineering